1、Wirelessacquisitioninstrunientformulti-ChannelvibratingstringsensorVS10xVS4xxusersmanual(V1.20ForHW2.00SF2.50)HebeiwincomTechnologyco.,Ltd2018年12月DisclaimersandwarningsPleasereadthisdocumentcarefullybeforeusingthisproduct.Thisstatementhasasignificantimpactonthesafeuseoftheproductandyourlegitimaterig

2、htsandinterests.Asamanufacturer,ourmonitorsaresafeandreliable,butWehopethatbuyerscanfullyunderstandtherelevantknowledgeofsensing,electronics,automaticmeasurementandcontrol,computerandOthertechnologies.Wedonotpromisethatitwillbecompatiblewithallsensorsandmeetallyourusagerequirementsandexpectations.Th

3、ismanualdoesnotdirectlyorindirectlyconstituteanycommitment.Onthebasisofthebuyersvoluntarypurchase,iftheinstrumentcauseshumanbodyinjuryoreconomiclossduringuse,asthemanufacturer;wewillnotassumeanyeconomicandlegalresponsibility.AnoverviewoftheVS10x20x4xisamulti-channelwirelessgeneratorbasedonvibrations

4、tringandtemperaturesensingsignals,andcanbeextendedtoothersimulations(current,voltage,resistance)signalanddigitalsignal(RS485,RS232)sensorchannel.Upto32channelsofautomaticacquisitionandstorageandremotewirelesstransmission;!programmablepowersupplyoutputcansupplypowerforothersensors;RS232/RS485datainte

5、rface,industrialMODBUSorAABBsimplecommunicationprotocolcanbedirectlyconnectedtotheexistingmeasurementandcontrolsystem(suchasPLCzwirelesstransmissionequipment,etc.);Thewirelessnetworksupports2G/4G/NB_IOT,WIFIzRF(Lora)zwhichcansendthemonitoringdataintheformofSMS,E-mail,FTPfiles,TCPandotherforms.Withth

6、ecooperationofOCMSztheplatformsoftwareofourcompany,themonitoringsystemcanbebuilteasilyandquicklythroughsimpleconfigurationtoachieveonlinemonitoring,dataviewinganddatadownloading.Castaluminumshelldurable,IP67protection,work-4085temperature,especiallysuitableforbadenvironment,withoutsecondaryprotectio

7、n.无线辗箍采发仪VS102-416nnalirYirULJMrrIlrurThemainfeaturesVS10X:80mm*75mm*60mmVS4XX:188mm*120mm*78mmNshellmaterial:castaluminumNprotectionlevel:IP67Npowersupply:DC1024Vwidevoltage3a(supportbattery+solarpanel)Nworkingmode:Real-timeonline:serialportoutput,TCP/RFreal-timeonlineTiming:itcanbeconfiguredwithin

8、1minute45days,anditcanbesentinsingleorindaily,weeklyandmonthlysummaryNsendingmethod:Digitalinterface:RS232orRS485output,MODBUScommunicationprotocolMobilenetwork:sendtomobilephone,TCPSerVecdesignatedE-mail,FTPserverself-builtradiofrequency:senddatatothecomputerwithin5kmrangeNaveragepowerconsumption:D

9、C12V10ahbatterycanbeusedfornolessthanhalfamonthwhenthereisnosolarenergycharging(onceperhour)Nstoragespace:canstorenolessthan2yearsdata(onceeveryhour)Ntemperaturerange:-4085parameterconditionleastvaluetypicalvaluemaximumpowersourceVIN101224VIWoiXInstantonthemachine2A250320380mA!sleep1.5uAVibratingstr

10、ing(frequency)sensorFrequencyrange1008000HzexcitationvoltageLowfrequencysweep320Vhighvoltagepulse30220Vfrequencyresolution0.01Hzfrequencyerror0.010.05Hzhighvoltage1S/CHDopplerfrequencyFeeclbackfrequencysweep1S/CHAllfrequencysweep10S/CHTemperature(thermistor)sensorresistancerange1210KQtemperaturereso

11、lution0.1OCtemperatureerror0.3celseRTCprecision23.5PPmBuilt-instorage832MByteExternalstorage32Goperatingtemperature-40+85cTheproductselectionNVS:non-linearvibratingstringsensorgeneratorNA:numberofembeddedcoremeasurementmodules(14)NB:numberofchordchannelsrepresentedbytwodigits(02z04,08,16)NC:Tmeanswi

12、thtemperaturemeasuringchannelND:vibrationstringsensorexcitationmethod(L:onlysupportlow-voltagefrequencysweep;H:supportlow-voltagefrequencysweepingandhigh-voltagepulseexcitation)NE:communicationinterfacetypes(2G,4G,NBIOT,WIFIzRF,RS485,RS232)modelnumbermibrationwireaisleITemperatumodelnumbBvibrationTe

13、Channe1ireaisIe:ITemperaturechannelVS10440VS102T22VS20880VS204T44VS312120VS306T66VS416160VS408T88Note:thedefaultwirelesstypeiswirelessnetworkofmobilephone,andusersneedtoinstallSIMcardbythemselves.Otherwirelesstypesmustcontactmarketingpersonnelpriortopurchase.Note:mobilenetworkincludes2Gy4GandNB_IOT.

14、Pleasepurchaseafterconfirmation.Exampleoftypeselection:VS104TH-4Grepresentsa4-channelvibratingstringandtemperaturegeneratorembeddedwithasinglemeasurementmodule.Thesensorexcitationmethodsupportslowandhighvoltage,andthewirelessnetworkis4G.Equipmentlist1devicehost(includingSIMcardholder)1poweradapter(D

15、C12V2a)1powercord(4cores)Onedatacable(3cores)Anumberofsensorsignallines(thequantityisconsistentwiththepurchasedequipmentmodel)Onesuckerantenna(1.5m)1setofinstallationaccessories(4screwsand4fixedfeet)1 copyofinstructionmanual(thismanual)Configurationsoftware1copydirectoryAnoverviewofthethreeMainfeatu

16、res3Productselection5Equipmentlisting5Directoryof6Structure8Interfacedefinition8Mechanicaldimension9Note102. Startusing112.1 poweronandpoweroff112.2 introductiontoparameterconfigurationtoolSETP112.2.1 runtheconfigurationtool112.2.2 interfacecomposition122.3 connect12withtheparameterconfigurationtool

17、2.3.1 preparationbeforeconnection122.3.2 connectdevice122.3.3 readingandmodificationofparameters2.3.4 real-timedatareading2.4 workingmodeandworkflow132.4.1 workingmode132.4.2 workflow142.5 timeintervalofproductionanddeliveryissetas142.6 datatransmission152.6.1 senddatatomobilephone162.6.2 senddatato

18、mailbox162.6.3 senddatatoFTPserver162.6.4 senddatatoTCPserver172.7 remotemodificationparameter172.7.1 modifyparameter17throughSMS2.7.2 modifyparameter18throughFTPfile2.7.3 modifyparameter18throughTCPserver2.8 storagedataexport18Frequentlyaskedquestions19structuralcompositionS-M卡前口O传感器接口Theinterfaced

19、efinitionVS4XXinterfacedefinitionThenameofthecablepowersupplyredInputpowerpositivepoleConnectthebatteryorpoweradapterblackInputpowernegativegreenChargeinputpositivepoleConnectthesolarpanelorchargerblueChargeinputnegativeRS232bluedatatransmit!onTXDConnecttothecomputerRS232interfacegreenDatatomeetRXDb

20、lackGNDCHxredThepositivepoleofthevibratingcoilWhenthedevicemodelhas,T:thegreenandbluesignallinesshouldbeconnectedtothetemperaturesensorWhentheequipmentmodeldoesnothaveT,:thegreenandbluesignallinesshouldbeconnectedwiththevibratingstringsensorblackNegativeterminalofthevibratingcoilgreenThevibratingstr

21、ingorthetemperaturepositivepoleblueThevibratingstringorthetemperaturenegativeMachinesizemapMattersneedingattention Strictlygrounding Thenegativepoleofequipmentpowersupplyshouldbeconnectedwiththeearthreliably,otherwiseitmayleadtoexcessivenoiseofsignalacquisition. Topreventelectrostatic Staticelectric

22、itycanseriouslydamageorevenrenderinstrumentcomponentsandaccessoriesunusable. Donotuseoverpressure Useonlythepowercordandpoweradaptersuppliedbythemanufacturer. 1.ightwithlight Avoidstrongvibrationduringuseandtransportation.Donotinstallortransferequipmentwhileitisstillinuse. Itisforbiddentodrip Thispr

23、oductdoesnothavecompletewaterproofability,itisstrictlyprohibitedtocontactwithwaterinanyform,donotinstallintheopenairenvironment. Drystorage Prolongedexposuretomoisturewillcausecorrosionofthehousingandinternalelectroniccomponents.Ensurethattheexternalandinternalpartsoftheequipmentaredrybeforeconnecti

24、ngtothepowersupply. Payattentiontotherange Donotattempttoconnectthesignallinebeyondthemeasuringrangetothesensorinterface. Noliveoperation Itisstrictlyprohibitedtoplugoroperatethephysicalinterface(aviationplug)oftheequipmentduringtheworkingperiod. Replacebuttonbatteryintime 1.owbatteryofinternalclock

25、willcausetheequipmentcannotworkproperly.Itisrecommendedtoreplaceiteveryonetotwoyears.TWOJstartusing2.1 poweronandpoweroff2.1.1 bootThedevicehasthreewaysofstartingup,namelymanualstartingup,automatictimingstartingupandsignaltriggeringstartingup.Manualpoweron:intheshutdownstate,pressthe,testsendbutton,

26、thePOWindicatorlightwillbeon,andreleasethebuttonwhenyouhearthebuzzerprompt.Automaticstartup:theequipmentstartsupautomaticallyaccordingtothepresettimeinterval,andshutsdownautomaticallyafterthecompletionoftheproductionanddevelopmentwork.Signaltriggerstartup:pulldownthestartingsignalline(GND),whichiseq

27、uivalenttomanuallypressingthebutton.(pleaseconsultthisfunctionbeforeusing).Note:whentheexternalpowersupplyofthedeviceisremoved,theinternalclockofthedeviceisstillrunningandattemptstocompletetheautomaticstartupprocesswhenthepresettimearrives.Atthistime,iftheexternalpowersupplyisconnectedagain,thedevic

28、ewillstartupautomatically.Thisisthenormalworkinglogicofthedevice,anditwillshutdownautomaticallyafterthecompletionofthiswork.2.1.2 toturnitoffTheequipmenthastwoworkingmodes:normalworkingmodeandparametersettingmode.Wheninnormalworkingmode,theequipmentwillautomaticallyshutdownafterthescheduledproductio

29、nanddevelopmentworkiscompleted.Wheninparametersettingmode,thedevicenevershutsdown.2.1.3 versioninformationAtstartup,outputastringcontainingthedevicemodelandversioninformationviathedigitalinterface,asshownbelow:=COPYRIGHTINFORMATION=type:VS4XXhwVer:2.00SfVer:2.50CopyRight:Copyright(c)2005-2017HBWTNCO

30、MCo.,Ltd.Al1RightsReservedsite:http:WWWPleasenotewhethertheversioninformationoftheequipmentusedisconsistentwiththismanual.Ifnecessary,pleaseaskusfortheapplicableusermanual.Whilethedeviceisrunning,youcangettheversioninformationbysendingitthestringinstruction$INFO.2.2 introductiontotheparameterconfigu

31、rationtoolSETPSETPisasoftwareprogramspeciallydevelopedforVSseriesmulti-channelvibratingstringgenerator,whichcancompletethereadingandmodificationofallparametersinsidethedevice,andcanalsobeusedasasimplechanneldatareadingtool.2.2.1 runtheconfigurationtoolDouble-clicksetp.exetoruntheprogram,asshowninthe

32、figurebelowCommunication control areaParameter configuration areaReal time dataParameterconfigurationtoolSETPmaininterface2.2.2 interfacecompositionAsshowninthefigureabove,SETPtoolconsistsofthreeareas:communicationcontrol,parameterconfigurationandreal-timedataCommunicationcontrolarea:itcancompleteth

33、esettingofportnameandcommunicationparameters,connectanddisconnectthedatacommunicationconnectionwiththedevice,andobservethecommunicationinformationwiththedevicethroughthereceivingboxandsendingbox.Parameterconfigurationarea:themainoperationareaforparameterviewandconfiguration.Alloperationsonparameters

34、arecompletedinthisarea.Real-timedataarea:automaticallyreadanddisplaythereal-timecollectedworkingstatusandsensordatainthedevice.2.3 connectwiththeparameterconfigurationtoolVS102VS416deviceisequippedwithaspecialparameterconfigurationtoolSETPtocompletetheviewandmodificationoftheworkingparametersofthede

35、vice.2.3.1 preparationbeforeconnection(1) datainterfaceandcomputerconnectionUsethestandardcommunicationlinetoconnectwiththecomputerRS232interface.(2) connectthepowersupplyoftheequipmentUsethestandardpowercordtoconnectthepowersupplyandensurethattheequipmentisshutdown.Ifthedeviceautomaticallystartsupw

36、henconnectedtothepowersupply,itneedstounplugthepowersupplyandconnectagain.(3) opentheconfigurationtoolSETPRunthesetp.exeprogram.2. 3.2connectingdeviceSelectthecorrectportnameandcommunicationparameters(default:9600,N,8,1)intheconnectionboxintheupperleftcornerofthemaininterface,andclicktheconnectionpo

37、rtbutton.(4) equipmentstartupPressthetest/sendbuttononthedevicetostartup.WhenSETPreceivestheversioninformationofthedevice,itindicatesthattheSETPtoolisconnectedtothedevicecorrectly.(5) enterthesettingmodeWithin3secondsafterthedeviceoutputstheversioninformation,clicktheentersettingmodebuttontoenableth

38、edevicetoentertheparametersettingworkingmode.Onlyinthismodecantheinternalworkingparametersofthedevicebereadandmodified.1.1.3 readingandmodificationofparametersTheparameterconfigurationareaoftheconfigurationtoollistsallparameteritemsrelatedtotheworkofthedevice.Eachparameteritemhastwobuttons,readandmo

39、dify.Clickthereadbuttontogetthecurrentparametervalueofthedevice,andclickthesetbuttontowritethevaluedisplayedonthecurrentinterfacetothedevice.Note:afterparametermodification,thesaveparameterbuttonmustbeclickedtotakeeffectonthenextstartup.1.1.4 real-timedatareadingClickthecheckboxofautomaticreadingint

40、hereal-timedataarea,andtheconfigurationtoolwillautomaticallysenddatareadinginstructionstothedeviceandupdatethereal-timedatareturnedbythedevicetothisareafordisplay.2.4 workingmodeandworkflow2.4.1 workingmodeTherearetwoworkingmodesofVSseriesdevelopmentinstrument:normalworkingmodeandparametersettingmod

41、e.Normalworkingmode:alsoknownasacquisitionanddistributionmode,thedeviceautomaticallycompletesthesensordatacollectionandtransmissionafterstartup,andthenshutsdown,waitingforthenexttimingtime.Parametersettingmode:theworkingmodethatcanaccessthedeviceworkingparameters.Onlyinthismodecantheconfigurationtoo

42、lbeusedtoreadandmodifythedeviceparameters.Thewaytoentertheparametersettingmodeistoclicktheentersettingmodebuttonontheconfigurationtoolinterfacewithin3secondsafterthedeviceisstarted.Note:whenthedatatransmissionmodeisGPRSTCP,thedevicewillalwaysmaintaintheconnectionstatewiththeTCPserverafterenteringthe

43、settingmode.Atthistime,theservercansendremoteinstructionstoitforremoteparametermodification.Fordetails,pleaserefertothesectionofremoteparametermodification.relevantparameterparameterParameteroptions/valuesdescrNormal(default)NormaloperatingmodeNexttimestartworkingmodeAdopthairmodel(1次)Forcedatacolle

44、ctionandtransmissiononceandautomaticallychangethisparametertonormalmodesettingpattern(1次)ForcetheparametersettingmodeonceandautomaticallychangeittonormalmodeAdopthairmodelForcetheparametersettingmodeonceandautomaticallychangeittonormalmodesettingpatternForcetoenterparametersettingmode.Unlessthispara

45、meterismodified,itwillentersettingmodeeverytimeitstartsNote:itisgenerallyusedfortestingandverifyingthedevelopmenteffectafterparametermodificationNote(2):itisgenerallyusedtoenterthesettingmodeagainafterparametermodificationtoseewhethertheparametersavingiseffective2.4.2 workflowInnormalworkingmode,equ

46、ipmentoffmostofthetimeinadormantstate,onlyatapredeterminedtimeintervalontheautomaticelectricparametersandtestingtime,determinewhethertoachievedatastoragetimeortosendtime,ifdidnotreachthepredeterminedtimepointintodormancyoffagainimmediately,ifatapredeterminedtime,sensordataacquisition,datastorage,andcontinuesendingwork.2.5 timeintervalsettingTheVSserieswirelessdataacquisitioninstrumentsupportssingledataandmultipledatawhensendingmonitoringdata.Singledatatransmissionreferstosendingonlythemonitoringdataofeachchannelcurrentlycollect

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 在线阅读 > 生活休闲


备案号:宁ICP备20000045号-1

经营许可证:宁B2-20210002

宁公网安备 64010402000986号